Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 620
Filtrar
1.
J Appl Oral Sci ; 32: e20230381, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537031

RESUMEN

BACKGROUND: Denture biofilm acts as a potential reservoir for respiratory pathogens, considerably increasing the risk of lung infections, specifically aspiration pneumonia, mainly 48h after hospital admission. The establishment of a straightforward, affordable, and applicable hygiene protocol in a hospital environment for the effective control of denture biofilm can be particularly useful to prevent respiratory infections or reduce the course of established lung disease. OBJECTIVES: To evaluate the anti-biofilm effectiveness of denture cleaning protocols in hospitalized patients. METHODOLOGY: The maxillary complete dentures (MCDs) of 340 hospitalized participants were randomly cleaned once using one of the following 17 protocols (n=20): brushing with distilled water, toothpaste, or neutral liquid soap (controls); immersion in chemical solutions (1% sodium hypochlorite, alkaline peroxide, 0.12% or 2% chlorhexidine digluconate), or microwave irradiation (650 W for 3 min) combined or not with brushing. Before and after the application of the protocols, the biofilm of the intaglio surface of the MCDs was evaluated using two methods: denture biofilm coverage area (%) and microbiological quantitative cultures on blood agar and Sabouraud Dextrose Agar (CFU/mL). Data were subjected to the Wilcoxon and Kruskal-Wallis tests (α=0.05). RESULTS: All 17 protocols significantly reduced the percentage area of denture biofilm and microbial and fungal load (P<0.05). The highest percentage reductions in the area of denture biofilm were observed for 1% hypochlorite solution with or without brushing and for 2% chlorhexidine solution and microwave irradiation only in association with brushing (P<0.05). The greatest reductions in microbial and fungal load were found for the groups that used solutions of 2% chlorhexidine and 1% hypochlorite and microwave irradiation, regardless of the association with brushing (P<0.05). CONCLUSIONS: A single immersion for 10 min in 1% sodium hypochlorite, even in the absence of brushing, proved to be a straightforward, rapid, low-cost, and effective protocol for cleaning the dentures of hospitalized patients.


Asunto(s)
Clorhexidina , Hipoclorito de Sodio , Humanos , Agar/farmacología , Biopelículas , Clorhexidina/farmacología , Limpiadores de Dentadura/farmacología , Dentadura Completa/microbiología , Dentaduras/microbiología , Ácido Hipocloroso/farmacología , Hipoclorito de Sodio/farmacología
2.
BMC Oral Health ; 23(1): 852, 2023 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-37951865

RESUMEN

BACKGROUND: The continuously increasing demand for removable denture appliances and the importance of adequate denture cleaning have led to the development of various denture cleansing products. The aim of this study was to evaluate the efficacy of two novel denture cleansing agents (GE and TM) and three commonly available cleansers (0.5% sodium hypochlorite; NaClO, 0.12% chlorhexidine gluconate; CHX, and Polident®; POL) on multispecies microbial biofilm formation, stain removal and physical properties of dentures. METHODS: The antimicrobial activities of denture cleansing agents were determined against major oral opportunistic pathogens including Streptococcus mutans, Staphylococcus aureus, Escherichia coli and Candida albicans, using time-kill assays. Multispecies microbial biofilms grown on acrylic resins for 72 h were generated to determine the antibiofilm effects of cleansing agents by confocal laser scanning microscopy (CLSM). Evaluations of the tea and coffee stain removal properties and the alterations in the physical properties of dentures were also performed. The toxicity of cleanser residues released from denture acrylics to fibroblast cells was investigated using MTT assay. RESULTS: All denture cleansing agents tested could effectively kill oral bacteria and Candida albicans. Furthermore, after immersion for more than 3 h, the cleansers Polident®, GE and TM could efficiently penetrate and inhibit multispecies denture biofilms with effects similar to 10 min of immersion in 0.5% NaClO. However, immersion in 0.12% CHX for 20 min showed less antibiofilm activity. The NaClO solution had the highest efficacy for removing stains from the artificial teeth. Conversely, the CHX solution enhanced tea and coffee staining, and the teeth immersed in this solution showed clinically unacceptable colour changes (ΔE > 5.5). However, the colour differences of teeth stained and immersed in POL, GE and TM cleansers were in the clinically acceptable range. There was no significant difference among the POL, GE and TM cleansers in terms of stain removal efficacy. The cleansers GE and TM did not alter the surface roughness and colour of the materials, moreover the residues of both cleansers did not exhibit cytotoxicity. CONCLUSION: Two novel denture cleansing agents containing natural products, GE and TM exhibited effective antimicrobial activity, antibiofilm and stain removal capabilities without toxicity or disturbance of the physical properties of acrylics.


Asunto(s)
Antiinfecciosos , Limpiadores de Dentadura , Humanos , Limpiadores de Dentadura/farmacología , Limpiadores de Dentadura/química , Colorantes/farmacología , Café , Detergentes/farmacología , Candida albicans , Antiinfecciosos/farmacología , Dentaduras , Biopelículas , , Propiedades de Superficie
3.
J Prosthet Dent ; 130(5): 798.e1-798.e8, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37716896

RESUMEN

STATEMENT OF PROBLEM: Studies on the impact of denture cleansers on the physical and mechanical properties of denture bases designed and constructed by using computer software programs are lacking. PURPOSE: The purpose of this in vitro study was to test the effect of a peroxide denture cleanser on the hardness, fracture toughness, water sorption, and solubility of denture base materials manufactured by 3D printing and computer-aided design and computer-aided manufacturing (CAD-CAM) milling. MATERIAL AND METHODS: The hardness, fracture toughness, water solubility, and sorption of CAD-CAM milled and 3D printed groups (n=40) were evaluated before and after exposure to a denture cleanser. Hardness (n=10) was analyzed with a Vickers hardness testing machine, and fracture toughness (n=20) with the 3-point bend test. After the fracture of specimens, a scanning electron microscope at ×300 was used for fractographic analysis. Water sorption and solubility (n=10) were evaluated before and after immersion in denture cleanser for 6 days to simulate 180 days of immersion. Two-way repeated ANOVA and 2-way ANOVA were used to test normally distributed data, whereas the Mann Whitney U test and Wilcoxon signed ranks test were used for data that were not normally distributed (α<.05). RESULTS: The Vickers hardness and fracture toughness of both materials decreased after immersion in denture cleansers, with a higher decrease in values for the 3D printed group (P<.001). The denture cleanser had no effect on the water sorption and solubility of either group. CONCLUSIONS: Milled specimens had higher hardness values and fracture toughness before and after immersion in the denture cleanser. Denture cleansers resulted in the reduced hardness and fracture toughness of both groups, but the percentage change in the milled group was lower. Denture cleansers had no effect on water sorption or solubility.


Asunto(s)
Bases para Dentadura , Limpiadores de Dentadura , Limpiadores de Dentadura/uso terapéutico , Ensayo de Materiales , Diseño Asistido por Computadora , Impresión Tridimensional , Agua , Propiedades de Superficie
4.
Bull Tokyo Dent Coll ; 64(3): 89-95, 2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-37599087

RESUMEN

The aim of this study was to investigate the effects of combining mechanical (ultrasonic) and chemical cleaning (using denture cleaners) on the surface roughness of silicone or acrylic soft relining materials. The silicone soft relining material with the lowest Shore A hardness and a acrylic soft relining material routinely used in Japan were selected. Four groups were established based on type of treatment: immersion in water (W); ultrasonic cleaning in tap water (U); ultrasonic cleaning in a hypochlorous acid denture cleanser (HU); or ultrasonic cleaning in an acidic denture cleanser (AU). Following the tests, surface roughness was determined as the arithmetic mean height of the surface (Sa) and maximum height (Sz). Data were analyzed using the Kruskal-Wallis test followed by Bonferroni correction for a multiple comparison. No significant difference was observed in the Sa or Sz of the silicone soft relining material between the 4 groups. Significant differences were observed in the Sa of the acrylic soft relining material between Groups W and HU (p=0.008) and between Groups W and AU (p=0.008), but no significant differences in the Sz among the 4 groups. Combining U with AU or U with HU yielded no increase in the surface roughness of the silicon soft relining material. The surface roughness of the acrylic soft relining material showed an increase, however, with the combination treatments used.


Asunto(s)
Alineadores Dentales , Siliconas , Humanos , Limpiadores de Dentadura , Ensayo de Materiales , Propiedades de Superficie , Agua , Bases para Dentadura
5.
PeerJ ; 11: e15750, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37601266

RESUMEN

Background: The study's objective is to assess the adherence of C. albicans in different types of denture polymers and the effectiveness of eugenol and commercialized denture cleansers in the removal of C. albicans. Three types of denture base polymers (Lucitone® 199 (High-Impact PMMA), Impact® (conventional PMMA) and Eclipse® (UDMA)) and two hard denture reline materials (Kooliner® and Tokuyama® Rebase II Fast) were used in this study. Methods: Three hundred samples were prepared (6 × 2 mm disc shape) and divided into five groups of denture polymers (n = 60) and further subjected into five treatment groups (Polident®, Steradent, distilled water, eugenol 5-minutes, and eugenol 10-min). Three samples were extracted from each treatment group for baseline data (n = 12). Baseline data were used to calculate the initial number of C. albicans adherence. A 0.5 ml immersion solution from each specimen was cultured on YPD agar and incubated for 48 h at 37 °C. Visible colonies were counted using a colony counter machine (ROCKER Galaxy 230). Results: The result showed that the denture base polymer significantly affected the initial adherence (p = 0.007). The removal of C. albicans was also considerably affected by the denture base polymers and denture cleansers (p < 0.05). Lucitone®, Tokuyama®, and Kooliner® denture base polymers immersed for 3 min in eugenol showed the best results of removal. Discussion: This study's overall results showed that all denture polymers used as denture bases had an effect on C. albicans initial adherence and removal from the denture base, and eugenol is comparable to commercialised denture cleansers in reducing the number of attached C. albicans on denture base polymers.


Asunto(s)
Antifúngicos , Candida albicans , Antifúngicos/farmacología , Limpiadores de Dentadura/farmacología , Eugenol/farmacología , Polimetil Metacrilato , Polímeros/farmacología , Dentaduras
6.
Clin Exp Dent Res ; 9(5): 840-850, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37438935

RESUMEN

PURPOSE: Denture base materials are commonly exposed to different denture cleansers which can affect their essential properties. This study aimed to assess the effect of denture cleansers on color stability and surface roughness of poly methyl methacrylate (PMMA) denture bases fabricated from different techniques: Conventional heat-polymerizing, CAD/CAM additive and CAD/CAM subtractive. MATERIALS AND METHODS: In this in vitro study, 24 disc-shaped specimens were fabricated by the mentioned methods for each group. The initial color and surface roughness of specimens were recorded. The specimens were randomly divided into three subgroups (n = 8): a control subgroup (distilled water), and two experimental subgroups of bioactive oxygen tablet (Corega) and 1% sodium hypochlorite solution. Then they were immersed in the solutions simulating 180 days of clinical use. Color change (∆E) was measured by a spectrophotometer according to the CIE L*a*b* color space and the American National Bureau of Standards (NBS = 0.92 × ∆E). Final surface roughness was recorded by a profilometer and its change was calculated. The Kruskal-Wallis test followed by the Wilcoxon signed rank test were used for statistical analyses (α = .05). RESULTS: The conventional and CAD/CAM subtractive groups showed an increase in surface roughness following immersion in hypochlorite solution (p < .05). After immersion in the solutions, the highest surface roughness was noted in the conventional group, and the lowest in the CAD/CAM additive group. The CAD/CAM additive group experienced a significant color change in hypochlorite solution (p < .05) and showed the highest color change while the CAD/CAM subtractive group showed the lowest color change in all denture cleanser solutions. CONCLUSION: Although the CAD/CAM additive denture base resins had the lowest surface roughness after exposure to denture cleanser solutions, they showed significant color change, which should be taken into account. Using hypochlorite as a denture cleanser should be cautioned due to its negative effects on the surface roughness and color stability of denture base materials.


Asunto(s)
Bases para Dentadura , Limpiadores de Dentadura , Calor , Ácido Hipocloroso , Ensayo de Materiales , Propiedades de Superficie
7.
J Contemp Dent Pract ; 24(4): 261-267, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37469266

RESUMEN

AIM: The study ventures into evaluating the antifungal and antibacterial efficacy of commercially available denture cleanser with Sargassum polycystum, Turbinaria conoides seaweeds, and the combination of seaweeds. MATERIALS AND METHODS: Poly(methyl methacrylate) disks measuring 10 × 2 mm were fabricated. The samples are divided into four groups of 21 samples each. The denture base was coated with Candida albicans and Streptococcus mutans individually. Group I was treated with Fittydent, group II (S. polycystum and T. conoides seaweeds combination), group III (S. polycystum), and group IV (T. conoides). The colony-formation units present on the surface of the denture were evaluated before and after treatment with different denture cleansers using the serial dilution method. Statistical analysis was done using descriptive statistics, analysis of variance, and post hoc Bonferroni analysis. RESULTS: At 10-5 dilution, T. conoides (group IV) was statistically significant in reducing both C. albicans and S. mutans. At 10-10 dilution, T. conoides (group IV) and S. polycystum and T. conoides combination (group II) had high antibacterial efficacy and were statistically significant. Fittydent (group I) had higher antifungal efficacy and was statistically significant in comparison to S. polycystum (group III) alone. At 10-10 dilution, the T. conoides (group IV), S. polycystum, and T. conoides combination (group II) showed no evidence of a significant difference in comparison to Fittydent (group I). Fittydent had higher antibacterial efficacy and was statistically significant in comparison to S. polycystum (group III) alone. CONCLUSION: Sargassum polycystum and T. conoides combination and T. conoides were found to have higher antibacterial efficacy in comparison to commercially available denture cleanser and also were found to have equal antifungal efficacy in comparison to commercially available denture cleanser.


Asunto(s)
Sargassum , Algas Marinas , Limpiadores de Dentadura , Antifúngicos , Candida albicans , Antibacterianos , Bases para Dentadura/microbiología
8.
J Indian Prosthodont Soc ; 23(2): 112-118, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37102535

RESUMEN

Aim: One of the main factors responsible for the development of Candida albicans on the surface of denture is improper maintenance of dentures. Denture hygiene can be achieved by regular cleansing of dentures using an appropriate denture cleanser. The aim of the study is to evaluate the antifungal efficacy of commercially available denture cleanser and the extract of Turbinaria conoides seaweed against C. albicans adherent to the surface of denture base resin. Settings and Design: This was an in vitro experimental study. Materials and Methods: Twenty-four Acrylic resin samples of dimension 10-mm radius and 2-mm thickness was randomly divided into two groups. The denture base resin was coated with C. albicans. The colonies present on the surface of each denture base resin were evaluated by serial dilution method. Group A was treated with commercially available denture cleanser and Group B was treated with extract of seaweed T. conoides. The colonies were then evaluated using serial dilution. Statistical Analysis Used: The colony count values obtained by serial dilution were tabulated. These values were statistically analysed using t-test. Results: Reduction of colony count is more in T. conoides than commercially available Fittydent; the difference was statistically significant with a mean difference of 65 at dilution 10-2 and 29.25 at dilution 10-3 using t-test with P < 0.001. Conclusion: Within the limitations of this in vitro study, it was proved that the extract of T. conoides seaweed and commercially available denture cleanser Fittydent was effective in reducing the colony count of C. albicans. T. conoides seaweed is statistically significant than commercially available Fittydent.


Asunto(s)
Antifúngicos , Limpiadores de Dentadura , Extractos Vegetales , Resinas Acrílicas , Antifúngicos/farmacología , Candida albicans , Bases para Dentadura/microbiología , Extractos Vegetales/farmacología , Algas Marinas , Pruebas de Sensibilidad Microbiana
9.
Am J Dent ; 36(2): 62-68, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37076294

RESUMEN

PURPOSE: To evaluate denture cleansing solutions regarding the surface roughness and color stability of two resilient liners with distinct optical characteristics used for the maximum recommended period of use. METHODS: The specimens of each resilient liner, transparent and white, were randomly distributed into groups (n= 15) of a daily 20-minute immersion simulation of 0.25%, 0.5% and 1% sodium hypochlorite (SH) and 4% acetic acid solutions. Surface roughness (Ra) and color stability (ΔE CIELab formula and NBS systems) were measured after 7, 14, 21, 30, 60, 90, 180, and 270 days. The factors of variations analyzed were material, solutions, and time of immersion. Statistical analysis used three-way ANOVA and Tukey tests (Ra), and repeated measure ANOVA (ΔE and NBS systems), P< 0.05. RESULTS: For Ra analysis, the variations occurred regardless of time and solution, as the white liner showed the greatest changes (P< 0.001). Regarding interactions between solution and time, in the period of 21 days until 270 days, Ra was equivalent for all solutions (P= 0.001). ΔE analysis showed a difference between solutions (P= 0.000) and interaction between time and solution (P= 0.000). For the transparent liner, the greatest changes were found for 1% SH after 60 days, however, at 270 days there was a color change equivalence with 0.5% SH, while 4% acetic acid solution showed intermediate values. For the white liner, 1% SH showed the highest color changes for all evaluated times, and the other evaluated solutions were similar after 270 days. For both resilient liners, 0.25% SH showed the smallest changes for the evaluated properties. CLINICAL SIGNIFICANCE: The changes found were dependent on the concentration of the solution used, as well as the length of exposure to the solution. In addition, the white resilient liner showed to be less susceptible to color changes. For both resilient liners, 0.25% sodium hypochlorite showed the least changes for the evaluated properties.


Asunto(s)
Limpiadores de Dentadura , Alineadores Dentales , Acetatos , Resinas Acrílicas , Bases para Dentadura , Limpiadores de Dentadura/farmacología , Ensayo de Materiales , Hipoclorito de Sodio/farmacología , Propiedades de Superficie
10.
Am J Dent ; 36(2): 75-80, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37076296

RESUMEN

PURPOSE: To evaluate the effectiveness of five alkaline peroxide-based effervescent tablets in reducing both biofilms and the food layer adhered on the cobalt-chromium surface. METHODS: Cobalt-chromium metal alloy specimens were contaminated with Candida albicans, Candida glabrata, Streptococcus mutans and Staphylococcus aureus. After biofilm maturation, the specimens were immersed in Polident 3 Minute, Polident for Partials, Efferdent, Steradent, Corega Tabs or distilled water (control). Residual biofilm rates were determined by colony forming units counts and biofilm biomass. In parallel, to investigate the denture cleaning capability of effervescent tablets, artificially contaminated removable partial dentures were treated with each cleanser. Data were analyzed by Kruskal-Wallis followed by Dunn post hoc test or ANOVA followed by Tukey post hoc test (α= 0.05). RESULTS: None of the hygiene solutions reduced C. albicans biofilm. Efferdent and Corega Tabs promoted reduction of C. glabrata biofilm, while Steradent was favorable against S. aureus biofilm. For S. mutans, lower biofilm rates were observed after immersion in Polident for Partials and Steradent. The effervescent tablets showed good cleaning performance, removing an artificial layer with carbohydrates, proteins, and fats, however, they were not effective in removing aggregated mature biofilm. CLINICAL SIGNIFICANCE: The different effervescent tablets presented favorable antimicrobial activity against C. glabrata, S. mutans and S. aureus on cobalt-chromium surfaces and showed cleaning capability. However, for an appropriate biofilm control, a complementary method should be evaluated since none of the peroxide-based solutions reduced C. albicans biofilms or substantially removed aggregated biofilm.


Asunto(s)
Dentadura Parcial Removible , Staphylococcus aureus , Candida albicans , Candida glabrata , Higiene , Limpiadores de Dentadura/farmacología , Comprimidos/farmacología , Peróxidos/farmacología , Biopelículas
11.
J Oral Sci ; 65(2): 117-120, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36990755

RESUMEN

PURPOSE: To study the antimicrobial effects of a novel vinegar-based denture cleansing agent on oral Streptococci and Candida species and the inhibitory effects on pre-formed bacterial and Candida biofilms on denture base. METHODS: The microorganisms used in this study were Streptococcus mutans (S. mutans), Streptococcus sobrinus (S. sobrinus), Streptococcus sanguinis (S. sanguinis), Candida albicans (C. albicans), and Candida glabrata (C. glabrata). The antimicrobial activity of novel vinegar solution was evaluated by time kill assay and biofilm grown on denture base. RESULTS: Time kill assay showed that vinegar exhibited the highest antibacterial effect on S. sobrinus, S. sanguinis, and S. mutans after 15 min of treatment. A 99.9% reduction in C. glabrata and C. albicans required more than 4 and 6 h of treatment, respectively. Vinegar significantly inhibited streptococcal biofilm, with an approximately 6 log-reduction at 30 min of treatment. The results demonstrated that viable Candida cells in biofilm reduced in excess of 6-log CFU/mL after 3 h treatment with vinegar. Moreover, the vinegar-based denture cleanser inhibited bacterial and Candida biofilm formation compared to the control group without treatment with statistical significance. CONCLUSION: A novel vinegar-based denture cleansing agent showed moderate antibacterial properties, but required a slightly longer immersion time to attain anticandidal effects compared to Polident and 0.2% CHX.


Asunto(s)
Ácido Acético , Antiinfecciosos , Ácido Acético/farmacología , Detergentes/farmacología , Limpiadores de Dentadura/farmacología , Candida , Candida albicans , Biopelículas , Dentaduras , Antibacterianos/farmacología , Streptococcus mutans
12.
Gerodontology ; 40(4): 472-483, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36629151

RESUMEN

OBJECTIVE: To evaluate the anti-biofilm action of chitosan, nanoparticulate chitosan, and denture cleanser Nitradine™ against biofilms comprising Candida albicans, Candida glabrata, Staphylococcus aureus, and Streptococcus mutans. BACKGROUND: Biofilm removal from removable partial dentures (RPD) is important for success in prosthetic rehabilitation. MATERIALS AND METHODS: The anti-biofilm action of the experimental chitosan-based solutions and Nitradine™ was evaluated on acrylic resin and cobalt-chromium alloy through assessing cell viability, cell metabolism, residual aggregated biofilm, and extracellular polymeric substance and biofilm morphology. RESULTS: Only chitosan reduced the viability of C. albicans on cobalt-chromium alloy surface, by 98% (a 1.7 log10 reduction in cfu). Chitosan-based solutions neither promoted substantial alteration of the metabolic activity of the four-species biofilm nor reduced the amount of the aggregated biofilm. After immersion in chitosan and nanoparticulate chitosan, viable microorganisms and extracellular polymeric substances distributed over the entire specimens' surfaces were observed. Nitradine™ reduced the viability and metabolic activity of biofilm grown on both surfaces, but it did not remove all aggregated biofilm and extracellular polymeric substances. After immersion in Nitradine™, approximately 35% of the specimens' surfaces remained covered by aggregated biofilm, mainly composed of dead cells. CONCLUSION: Although chitosan and Nitradine™ promoted changes in the viability of microorganisms, neither solution completely removed the four-species biofilm from the Co-Cr and acrylic resin surfaces. Thus, isolated use of hygiene solutions is not indicated for biofilm control on RPDs; this requires complementary mechanical removal.


Asunto(s)
Resinas Acrílicas , Quitosano , Humanos , Resinas Acrílicas/farmacología , Quitosano/farmacología , Matriz Extracelular de Sustancias Poliméricas , Recuento de Colonia Microbiana , Propiedades de Superficie , Candida albicans , Biopelículas , Aleaciones de Cromo , Limpiadores de Dentadura
13.
J Prosthodont Res ; 67(2): 164-172, 2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35811135

RESUMEN

PURPOSE: To evaluate the influence of denture cleansers on the surface roughness, Candida albicans adhesion, and biofilm formation on denture base acrylic resins. STUDY SELECTION: Electronic databases and gray literature were searched using an individual search strategy. In vitro studies that evaluated the effects of immersion in denture cleansers on the surface roughness (µm) and antimicrobial activity (CFU/mL) on samples of heat-polymerized denture base acrylic resins were included. RESULTS: After screening, 17 studies were included, and a qualitative synthesis was performed. After assessing the risk of bias, only nine studies were included in the meta-analysis. The meta-analysis results showed that the evaluated solutions (0.5% sodium hypochlorite, 1% sodium hypochlorite, alkaline peroxide, and natural substances) did not influence the roughness of the acrylic resin. However, in the qualitative analysis, it was not possible to confirm an association between roughness and C. albicans adhesion and biofilm formation on the acrylic resin samples. CONCLUSION: Denture cleansers did not affect the surface roughness of denture base acrylic resins.


Asunto(s)
Resinas Acrílicas , Candida albicans , Materiales Dentales , Limpiadores de Dentadura/farmacología , Hipoclorito de Sodio/farmacología , Propiedades de Superficie , Bases para Dentadura , Biopelículas
14.
J Prosthodont ; 32(3): 244-252, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35445773

RESUMEN

PURPOSE: To compare the change in surface roughness of denture bases fabricated using three different techniques (additive manufacturing, subtractive manufacturing, and conventional heat-polymerizing) when immersed in two commonly available denture cleansers. MATERIALS AND METHODS: One hundred and seventeen disc-shaped denture base specimens (39/group), were fabricated by subtractive manufacturing (Wieland), additive manufacturing (NextDent Denture 3D+), and conventional heat-polymerizing (Meliodent) techniques, following the manufacturers' instructions. Specimens were randomly divided into 3 groups and immersed in two effervescent denture cleansing solutions and distilled water to simulate 180 days of denture cleansing. A 3D optical noncontact surface profilometer was used to record the surface roughness of the tested denture base materials before and after immersion. Two-way ANOVA, followed by Bonferroni post hoc test, was used to assess the effects of denture cleansers on surface roughness of tested denture base resins. RESULTS: When immersed in Fixodent and Fittydent effervescent denture cleansing solutions, the highest change in absolute surface roughness (∆Sa, in µm) was observed in additively manufactured denture base material (0.181 ±0.018 and 0.079 ±0.008), followed by heat-polymerized denture base material (0.149 ±0.012 and 0.059 ± 0.011), while subtractively manufactured denture base material showed the least change (0.110 ±0.026 and 0.038 ±0.007), respectively. There was a difference in the extent of change in surface roughness between the denture cleansers. The change in surface roughness was much higher with the Fixodent denture cleanser as compared to the Fittydent denture cleanser. CONCLUSION: Subtractively manufactured denture base resin displayed the lowest change while additively manufactured denture base resin displayed the highest change in surface roughness in both denture cleansers, but the extent of change in surface roughness was variable.


Asunto(s)
Resinas Acrílicas , Bases para Dentadura , Limpiadores de Dentadura , Limpiadores de Dentadura/farmacología , Calor , Ensayo de Materiales , Propiedades de Superficie
15.
J Prosthet Dent ; 130(5): 787-795, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35148889

RESUMEN

STATEMENT OF PROBLEM: Which disinfection protocol provides optimal water contact angle and microhardness for computer-aided design and computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA) materials is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the effect of different disinfection protocols (1% sodium hypochlorite, denture cleanser gel, and effervescent tablet) on the water contact angle and microhardness of different CAD-CAM PMMA denture base materials by comparing them with a heat-polymerized PMMA. MATERIAL AND METHODS: Disk-shaped specimens (Ø10×2 mm) were fabricated from 3 different CAD-CAM PMMAs-AvaDent (AV), Merz M-PM (M-PM), and Polident (Poli)-and a heat-polymerized PMMA (Vynacron) (CV) (n=21). Three disinfection protocols (1% sodium hypochlorite [HC], denture cleanser gel [GEL], an effervescent tablet [TAB]) were applied to simulate 180 days of cleansing. The water contact angle and microhardness of specimens were measured before and after disinfection and compared by using a 2-way ANOVA (α=.05). RESULTS: For water contact angle, material (P=.010) and disinfection protocol (P=.002) had a significant effect. The material (P<.001), disinfection protocol (P=.001), and their interaction (P<.001) significantly affected the microhardness after disinfection. When the condition after disinfection was compared with that before disinfection, the water contact angle increased significantly in all material-disinfection protocol pairs (P≤.025), and microhardness increased significantly in all material-disinfection protocol pairs (P≤.040), except for GEL- (P=.689) or TAB-applied (P=.307) AV, HC-applied M-PM (P=.219), and TAB-applied Poli (P=.159). CONCLUSIONS: The material and disinfection protocol affected the water contact angle of all tested PMMAs after disinfection, resulting in more hydrophobic surfaces for heat-polymerized or CAD-CAM PMMAs. The microhardness of heat-polymerized PMMA was less than that of all CAD-CAM PMMAs after disinfection, regardless of the protocol.


Asunto(s)
Bases para Dentadura , Polimetil Metacrilato , Polimetil Metacrilato/química , Ensayo de Materiales , Limpiadores de Dentadura/farmacología , Limpiadores de Dentadura/uso terapéutico , Desinfección , Hipoclorito de Sodio/farmacología , Diseño Asistido por Computadora , Propiedades de Superficie , Comprimidos , Agua
16.
Dent Mater J ; 42(2): 167-176, 2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-36476683

RESUMEN

This study aimed to evaluate the hardness, roughness, and color stability of heat- and microwave-polymerized polymethyl methacrylate (PMMA), polyamide, and CAD-CAM PMMA resins when exposed to cigarette smoke (CS) and immersed in a denture cleanser (DC). Specimens of each resins were divided into four subgroups (n=10). The DC and CS+DC specimens were immersed in a DC; the CS and CS+DC specimens were exposed to CS; and the control (C) specimens were kept in distilled water. Hardness, roughness, and color measurements were performed. DC and CS significantly affected the roughness and color of all resins (p<0.05). However, these did not affect the hardness of the CAD-CAM PMMA resin (p>0.05). The CAD-CAM PMMA resin presented the lowest roughness, highest hardness, and lowest ΔE00 values. While the roughness of all resins exposed to CS when immersed in DC decreased, the ΔE00 values of the conventional PMMAs also decreased. Although this decreases were not significant, it may be advisable to use DC for smokers to decrease discoloration and roughness especially for conventional PMMAs resins.


Asunto(s)
Fumar Cigarrillos , Limpiadores de Dentadura , Bases para Dentadura , Polimetil Metacrilato , Ensayo de Materiales , Propiedades de Superficie , Diseño Asistido por Computadora
17.
J Contemp Dent Pract ; 24(8): 556-559, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38193177

RESUMEN

AIM: The purpose of the current study was to evaluate the impact of three different denture cleansers on the strength and surface roughness of heat-polymerizing resin. MATERIALS AND METHODS: A total of 120 resin discs (10 mm in diameter and 2 mm thick) were created using a stainless steel mold for surface roughness testing and flexural strength testing (in accordance with the American Dental Association (ADA) Specification No.12). Samples were divided into one of three groups (40 samples in each group): group I: Clanden, group II: Clinsodent, group III: Fittydent. Samples were immersed in denture-cleansing solutions for 30 minutes every day, and this process was repeated over a period of 15 days. Samples were stored in distilled water at room temperature in between the immersions. A surface analyzer was utilized to compare the surface roughness of each sample before and after immersion treatments. For recording flexural strength, each sample was subjected to three-point bending test by mounting samples on Universal testing machine. Comparing mean values between groups using one-way ANOVA and the Tukeys honest significant difference (HSD) post hoc test. A significance level of 0.05 was used for all statistical calculations Results: After 15 days, the maximum change of mean surface roughness of heat-polymerizing resin was found in Clanden denture cleanser group (2.64 ± 0.12) followed by Clinsodent group (2.26 ± 0.09) and Fittydent group (1.92 ± 0.06). After 15 days, the maximum change of mean flexural strength changes of heat-polymerizing resin was found in Clanden denture cleanser group (94.78 ± 0.14), followed by Fittydent group (98.64 ± 0.03) and Clinsodent group (99.26 ± 0.21). CONCLUSION: Within the limitation, the current study concluded that changes were observed in surface roughness and flexural strength of all heat-polymerizing resin samples after immersion in all three denture cleansers; but least surface roughness and flexural strength changes were observed with the Fittydent cleanser group and Clinsodent group, respectively. CLINICAL SIGNIFICANCE: Cleaning dentures is crucial for maintaining both the prosthesis and oral health; therefore, it is necessary to select a cleanser that is effective without negatively affecting the base resin's qualities over time.


Asunto(s)
Limpiadores de Dentadura , Calor , Estados Unidos , Limpiadores de Dentadura/farmacología , Proyectos de Investigación , Análisis de Varianza
18.
Pesqui. bras. odontopediatria clín. integr ; 23: e210147, 2023. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1431045

RESUMEN

Abstract Objective: To determine the effect of ozonated water on the color stability of denture tooth and denture bases. Material and Methods: Thirty denture base discs consisting of 15 Acropars and 15 ProBase Hot specimens with the dimensions of 40 × 5 mm were prepared. Fifteen denture teeth in shade A1 (Ivoclar Vivadent, Schaan, Liechtenstein) were mounted in a specific acrylic jig. All specimens were immersed in three solutions (1% sodium hypochlorite, ozonated water, and distilled water) for four months (one year of clinical use). Color measurements were done with a spectrophotometer and assessed using the CIE L*a*b* colorimetric system (0, 4, 8, 12, and 16 weeks). Data were analyzed using the three-way ANOVA and Tukey test (α=0.05). Results: Tukey's post hoc test revealed a significant change in color in the Acropars denture base for the distilled water group compared to the ozonated water and 1% hypochlorite (p<0.05). Regarding the ProBase Hot denture base, significantly less color change was observed in the 1% hypochlorite group compared to the ozonated water and distilled water (p≤0.001). For the denture teeth, significantly less color change was seen in the distilled water group than in the ozonated water (p=0.015) and 1% hypochlorite (p<0.05) groups. Conclusion: The color change of denture bases and denture tooth in ozonated water are acceptable. Ozonated water can be considered a good disinfectant for cleaning dentures.


Asunto(s)
Ozono/uso terapéutico , Color , Pulido Dental , Dentadura Completa , Resinas Acrílicas , Agua Destilada , Análisis de Varianza , Limpiadores de Dentadura/efectos adversos , Polimerizacion
19.
J Cancer Res Ther ; 19(7): 2031-2035, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38376313

RESUMEN

CONTEXT: Different denture cleansers have an effect on color and different surface properties of polyamide denture base material. Thus, selecting a denture cleanser solution for polyamide denture base materials should be based on the properties of the denture cleanser itself. The present in vitro study is aimed to evaluate and compare the effect of different denture base cleansers on color, surface roughness and hardness of polyamide denture base material. METHODS AND MATERIAL: Thirty specimens of commercially available polyamide denture base material were fabricated and divided into three groups of 10 each. Specimens from each group were immersed in different denture cleansers (sodium perborate, thyme oil and ozonated water) for 10 mins per day for 180 days. Initial and final color, surface roughness and surface hardness of each specimen were measured and the difference was calculated. Data was tabulated and subjected to statistical analysis using One way ANOVA for pair wise comparison. RESULTS: Polyamide denture base resin exhibited some degree of change in color, surface roughness, and surface hardness in all denture cleansers but was not statistically significant. CONCLUSIONS: The choice of denture cleanser for different denture base resins should be based on the chemistry of resin and the cleanser, denture cleanser concentration and duration of immersion.


Asunto(s)
Bases para Dentadura , Limpiadores de Dentadura , Humanos , Dureza , Nylons , Análisis de Varianza
20.
Artículo en Inglés | MEDLINE | ID: mdl-36497881

RESUMEN

Oral care involving a denture cleaning regimen is important for reducing the incidence of systemic diseases. However, limited information is currently available on denture cleaning frequencies and regimens. Therefore, the present study investigated the relationship between the number of Candida spp. present on the complete dentures of nursing home residents and cleaning regimens. Residents were surveyed to assess their denture cleaning methods. Plaque was collected by applying a sterile swab to the mucosal surface of each examined complete denture worn by 77 residents, and the Candida spp. collected were cultured, identified, and quantified. The relationship between denture cleaning regimens and the quantity of Candida spp. was investigated. Correlation and multivariable analyses revealed that the strongest factor influencing the number of Candida spp. on dentures was the frequency of use of denture cleansers. The number of Candida spp. was the lowest on dentures cleaned daily with a denture cleanser. The present results demonstrated that the daily use of a denture cleanser effectively controlled the adherence of Candida spp. to dentures. Oral and other healthcare providers need to provide instructions on and assist nursing home residents with the daily care of dentures, using denture cleansers, including the environment where cleaning is performed.


Asunto(s)
Candida , Limpiadores de Dentadura , Limpiadores de Dentadura/farmacología , Estudios Transversales , Dentadura Completa , Casas de Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...